ASTM D4940 DOWNLOAD

Elcometer Abrasive Soluble Salt Test Kit – ASTM D Abrasives used for blast cleaning surfaces can be contaminated with soluble salts due to the. 1 Dec ASTM D Standard Test Method for Conductimetric Analysis of Water Soluble Ionic Contamination of Blast Cleaning Abrasives. 23 Nov ASTM D – Standard Test Method for Conductimetric Analysis of Water Soluble Ionic Contaminatio.

Author: Moogum Faujas
Country: Syria
Language: English (Spanish)
Genre: Marketing
Published (Last): 22 December 2014
Pages: 224
PDF File Size: 15.92 Mb
ePub File Size: 3.25 Mb
ISBN: 164-2-58160-942-7
Downloads: 79860
Price: Free* [*Free Regsitration Required]
Uploader: Fenrirg

This could cause widespread failures and become very expensive to repair. Your email address will not be astm d4940. December 23, at 7: The note in the ASTM D test method was used as an example to demonstrate that the higher the astm d4940, the more contaminated the abrasive.

Elcometer 138 Abrasive Soluble Salt Test Kit – ASTM D4940

No items in cart. If the chloride levels in the wash astm d4940 are too high, this will promote premature corrosion, shortening the life of both steel and concrete structures.

Astm d4940 Elcometer Abrasive Soluble Salt Test Kit provides all that is needed to carry out the test in the field or in the laboratory. We use cookies to understand how you use our site and to improve your experience. Copyright Compu-tecture, Inc. However, many will astm d4940 one of more of the SSPC abrasive blast cleaning standards e.

Each standard has different requirements based on the type of media but are identical when it comes to the quality control tests for oil content and water-soluble astm d4940.

So even if the project specification does not specifically address abrasive cleanliness, it is automatically invoked when an SSPC abrasive blast cleaning standard is specified. This standard does not purport to address all of the safety problems associated with its use.

The test shall be repeated till the team is capable of carrying out the desired blasting job.

March 3, at Elcometer A test is designed to use a ratio of 1: Used atm astm d4940 recycled water to establish effectiveness of salt removal, this test is ideal when mixing concrete and when washing steel. March 7, at 9: Elcometer S test method: The Elcometer Top Salt Contamination Meter quickly and accurately measures the level of soluble salts on d494. The resulting slurry is allowed to settle and the filtered water can then be astm d4940 using a conductivity meter.

Related Drivers  RIMWARD PDF

Elcometer Bresle Salt Kit A range of products to test astm d4940 level of contaminants on the surface.

This contamination can be transferred to the blast astm d4940 surface and result astm d4940 accelerated corrosion conditions and also cause premature coating failure, if this contamination is not removed prior to applying the coating.

The Elcometer Abrasive Soluble Salt Test Kit provides all that is needed to aetm out the test in the field or in the laboratory.

The following editions for this book are also available You have successfully saved to your astm d4940 list. Enter your account email address d4904 request a password reset: Abrasive blast cleaning is the most common and productive form of astm d4940 preparation. The procedure may be used to remove gels and incompatible materials that may cause imperfections astm d4940 the final extruded product. The two tests that are used to verify abrasive cleanliness are oil content and water soluble salt content.

The Elcometer SSP provides fast and accurate measurement of the aetm and density of soluble salts on surfaces — and can provide Bresle equivalent values.

Elcometer Digital Surface Profile Gauge Digital, fast and accurate surface profile inspection on astm d4940 and curved surfaces. The astm d4940 is then poured through filter paper to prevent silt from fouling the probe and conductivity of the filtered astm d4940 is measured.

Register or Log in for direct access to additional content. SSPC-AB 4 requires more frequent testing including at least three water-soluble contaminants tests at different times during an 8-hour period. Abrasives used for blast cleaning surfaces can be contaminated with soluble salts due to the source or the re-use of the blasting media. How can I tell if the abrasive is contaminated?

Related Drivers  TIEMPO PARCIAL DE TROMBOPLASTINA EPUB DOWNLOAD

Without routine monitoring of abrasive cleanliness, these contaminants could go unnoticed. Kaunteya, the following is a response from the author, John Todd: This field test astm d4940 equal parts abrasive and deionized water mL of each that astj combined and are twice stirred for 1-minute with an awtm astm d4940 time between stirs to leach any soluble salts from the abrasive.

Abrasive selection is a key component to an abrasive blast system. The container is shaken for about 1 minute and allowed to stand up to 5 minutes. Which abrasive cleanliness standard should be used?

Norma ASTM De1

FORMAT Single User Subscription Site License Subscription BOOKS All Books PACKAGES All Packages EDITION to PUBLISHER. Gurudas, the atm is a reply from the author, John Astm d4940 Proper surface preparation is one of the most critical steps towards maximizing the astm d4940 of a coating system.

Recyclable Encapsulated Abrasive Media Each standard has different requirements based on the type of media but are identical when it comes to the quality control aatm for oil content and water-soluble contaminants.

If the coating is applied astm d4940 a contaminated surface, which is not properly prepared, it could fail prematurely resulting in costly re-coating and high maintenance costs. Astm d4940 resulting slurry is allowed to settle and the filtered water can then be tested using a conductivity meter. The cleanliness of the abrasive whether new or recycled is equally important.

If you like to setup a quick demo, let us know at support madcad. Elcometer E Conductivity Meter, ml astm d4940 The Elcometer Standard Salt Contamination Meter quickly and accurately measures the level of soluble salts on surfaces. Elcometer CSN tests are all designed to use a ratio of 1: